General computing, heterogeneous computing, collaborative computing, edge computing and other diversified product layout

Powerleader GS6625U U.2 NVMe All-flash arrays

GS6625U U.2 NVMe Full Flash Arrays are high-performance storage solutions for enterprises. Equipped with U.2 NVMe SSD, it provides higher IOPS and throughput, and is more cost-effective. It also supports SAN, NAS, Object services, and connects to the cloud through Gateway. Scale out at the block and file levels to linearly improve performance and capacity. Complete data protection enables users to focus on their business, making it ideal for applications such as HPC, film and television media, virtualization, and databases.

Functional features
Excellent performance and scalability

End-to-end IOPS up to1000K, accelerated storage running up to 20 GB/s of reads and 10GB / s writtensequential bandwidth through horizontal and longitudinal expansion, singleclusters can support up to 80 GB/s of reading performance, support 3,586 harddrives, and more than 40PB of storage space.


Reduce input costs

Automatic storagetiering enables U.2 NVMe SSDs for high-performance I/O and NL-SAS/SATA HDDs formassive data archiving.


optimize U.2 NVMe SSD

Built-in intelligentalgorithms extend SSD life and prevent data loss due to simultaneous failure ofmultiple SSDs.


Intuitive system management

Unique storagesoftware with an intuitive web-based interface simplifies management.


Performance

The PCIe interface ofthe U.2 NVMe SSD features high speed and low latency, providing up to 20/10GBps of read/write performance and 1000K IOPS in a single device.


High scalability

Storage clusters canbe created through scale-out capabilities, enabling linear growth inperformance and storage capacity. Scale-out architectures that support both SANand NAS. Users can access shared folders in the cluster under a singlenamespace, improving file access efficiency. It also supports automaticbalancing and online migration to achieve load balancing without serviceinterruption. By scaling out and up, U.2 clusters can support up to 80/40 GBpsof read and write performance, 4000K IOPS, and capacity up to 3000+ hard drivesas nodes grow.


High efficiency

Supporting hybridconfigurations, automated storage tiering automatically leverages the highthroughput and low latency of U.2 NVMe SSDs to deliver faster performance forfrequently accessed data while taking advantage of the expansion enclosureHDD's large capacity for data archiving to improve system performance andreduce investment costs.


Comprehensive data protection and backup

Provides a variety ofdata protection to ensure that data is fully protected. In the case of SSDs,unique RAID technology helps the system function properly while ensuring thatyour data is adequately protected even in the event of hard drive damage. In termsof local data backup, flexible backup scheme ? snapshots are supported. Userscan schedule backups of all resources within the storage system, includingvolumes, shared folders, and even individual files. As for remote backup, youcan use the remote copy feature to remotely back up files to a remote device,or you can back up to the public cloud through the Gateway feature.


High stability

Power supply, fan,controller to host channel board..... All hardware components are modular indesign, reducing the difficulty of maintenance. Accurate technical support andRMA services that eliminate the need for downtime maintenance services increasebusiness productivity and competitiveness.


Intelligent hard drive management

Intelligent algorithmsprocess the data that is about to be written to the storage device, which notonly reduces the total amount of data written, thereby extending the servicelife of the SSD, but also prevents multiple SSDs from failing at the same time,resulting in data loss. In addition, the status of the SSD is monitored in realtime, the remaining life is estimated, and notifications are issued to remindadministrators to replace the SSD that is about to fail.


Easy to manage

Powerleader managementsoftware is used to help customers improve the efficiency of storage andservices and increase productivity. Intuitive interface design allows

Centralize management ofmultiple devices, monitor performance and capacity usage, and complete allrelevant system configurations.

Application environment
GS6625U is the keybusiness volume for centralized data management and medium-sized enterpriseslaunched by Powerleader. With high IOPS business environment, 25 U.2 NVMe SSDis full flash array, which is the ideal choice for your VDI, HPC, OLTP, GIS andsmall fragment files.For customer business model, read and write for flashmemory, can meet the needs of customers in different environments, and achievehigh IOPS, IO throughput bandwidth and latency.
Technical specifications

Features

GS6625U Technical Specification

Hardware specifications


specifications

2U 25 disk position

controller

Redundancy controller

Cache protection

Standard 4 * 4GB, maximum support 512GB

Cache Battery protection

Ultracapacitor + flash module (for single-control-upgraded and dual-control models only)

Support hard disk

2.5 Inch U.2 NVMe SSD

software maintenance


Maximum logical disk number and space size

32、512TB

Configurable stripe size

Each logical disk 16KB, 32KB, 64KB, 128KB, 256KB, 512KB, 1024KB

Configurable write policies

The policy can be modified for write-back or write-through per logical disk

Maximum storage pool size and number

2PB、32

Maximum volume size and number( Per storage pool / per system )

2PB、1024

The maximum number of host LUN mappings

4096

Maximum number of host connections (per FC)

128

RAID level

RAID 0, RAID 1, RAID 3, RAID 5/5F, RAID 6/6F, RAID 10, RAID 30, RAID 50, RAID 60

RAID Online upgrade

Full LD (logical drive), LV (logical volume) online capacity expansion, support online RAID level change

Firmware upgrade

on line

Standard software function

Multipath redundancy suppor

The RAID-level migration is available

Automatic bad sector reassignment

maximum number of hard disks are supported

The maximum number of hard disks are supported

896

Transally extends each cluster of connecting nodes

3584

Protocol support

File-level protocol

CIFS/SMB (Version 2.0/3.0), NFS (Version 2/3/4), AFP (Version 3.1.12), FTP/FXP (vsftp 2.3.4), WebDAV (httpd package 2.4.6)

Block level protocol

FC, iSCSI, SAS

Object-level protocol

RESTful API

File level

Maximum file system size

2PB

Maximum number of shared folders

2048 (NFS/CIFS/FTP) | 255 (AFP)

Maximum number of users

20000

Maximum number of user groups

512

Rsync maximum number of tasks

1024

Rsync upper limit of concurrent numbers

64

data service


Automatic encryption of hard disk

support

A unique factory key ensures data security, and data removal is simple and complete

Automatically streamline configuration

standard configuration

Capacity is allocated on demand, optimizing storage utilization, and eliminating space is allocated without use

Local replication

snapshot

standard configuration

number of snapshots per source volume:64

number of snapshots per storage pool:128

support

number of snapshots per source volume:256

number of snapshots per storage pool:4096

Volume copy /

Vge

standard configuration

number of copy pairs per source volume:4

number of replicate pairs per system:16

support

number of copy pairs per source volume:8

number of replicate pairs per system:256

Remote replication


Block level

support

number of copy pairs per source volume : 8

number of replicate pairs per system: 64

Note: 1. Regardless of remote asynchronous/remote synchronous/local volume pairs, the maximum number of replication pairs per source volume is up to 8.

2Remote replication is not supported on 4 x 16Gb FC and 2/4 x 32Gb FC host channel boards.

File level

standard configuration

Support for Rsync 128-bit SSH encryption

Automatic hierarchical storage

Matching

It is divided into 2 or 4 levels according to the type of hard disk

Automatically migrate data and calls by scheduling

Connectivity


On-board 12Gb/s SAS port( Connect JBOD Expansion Cabinet )

4

On-board 10GbE port(without SFP+ module)

8

Host channel (optional 2 groups)

16Gb/s FC x 4

32Gb/s FC x 2

10GbE (SFP+) x 2

10GbE (RJ-45) x 2

25GbE (SFP28) x 2

40GbE (QSFP+) x 2

Note: 1. Both controllers must have the same slot settings.

2. Fibre Channel supports point-to-point and switch modes.

General characteristics


Dimensions (without handle / protruding part) (W x H x D)

449 x 88 x 589.6 mm

Package size (W x H x D)

794 x 369 x 596 mm

Weight (single cabinet)

19.58 kg(without disk)

power supply

530W x 2 (80 PLUS Bronze);100-127VAC @10A 200-240VAC @5A;47-63 Hz

Operational power supply specifications


environment

temperature:

10°C-40°C (operation); relative humidity: 20%-80%RH (operation);

Operating status: 0°C to 40°C without BBU or CBM, 0°C to 35°C with BBU or CBM

Non-operating: -40°C to 60°C

Tibet:

Operating Status : Sea Level up to 3,048m (10,000ft)

Non-Operating Status : Sea level up to 12,192m (40,000ft)

Relative humidity: 5% to 95% non-condensing, operating and non-condensing

System compatibility


Supported operating systems

Microsoft Windows Server 2019/2016/2012R2/2012/2008R2/2008, Windows 7 SP1, Windows 8.1, Microsoft Windows Hyper-V,

Ret Hat Enterprise Linux, SUSE Linux Enterprise, Sun Solaris, Mac OS X, VMware, Citrix XenServer, OpenStack Cinder

System Administration


management style

Dynamic management of GUI graphical interface, web browser remote management, serial port management, SSH and Telnet



Service and Support

PowerLeader provides nationwide joint warranty, and PowerLeader 's professional after-sales service outlets across the country provide "one-stop" service response and support.

- 3-year limited on-site warranty and on-site support

- 4008-870-872 hotline response and support

For more information: please visit: http://en.powerleader.com.cn/

Correspondence address: 16th Floor, Building B, Building 7, Baoneng Technology Park, No. 1 Qingxiang Road, Longhua District, Shenzhen


PowerLeader reserves the right to change product specifications or other product information (including but not limited to product weight, appearance, size or other physical factors) without notice; the information mentioned in this article may change due to product upgrades or other reasons. resulting in changes without prior notice. The product pictures involved in this article are subject to the actual product.

Related downloads
View more >
  • Powerleader GS6625U Product Paper

    2024-11-14

主站蜘蛛池模板: 少妇精品导航| 荫蒂每天被三个男人添视频| 国产精品 视频一区 二区三区 | 欧美交换配乱吟粗大25p| 欧美一进一出抽搐大尺度视频| 欲求不满的寂寞人妻中文字幕| 国产电影一区二区三区| 久久精品国产亚洲av网站| 亚洲熟妇色xxxxx欧美老妇| julia无码中文字幕一区| 亚洲熟女一区二区三区| 毛片无码国产| av网站免费线看精品| 国产精品亚洲一区二区三区| 精品国产三级a∨在线观看| 精品一区精品二区制服| 激情综合婷婷色五月蜜桃| 毛片tv网站无套内射tv网站| 欧美日韩亚洲国产精品| 99国精品午夜福利视频不卡| 丰满大爆乳波霸奶| 亚洲av无码乱码国产麻豆| 东京热人妻无码一区二区av| 亚洲精品国产精品乱码视色| 色噜噜狠狠色综合av| 在线播放亚洲第一字幕| 女女女女女裸体处开bbb| 国产精品 无码专区| 亚洲人成无码www久久久| 国产精品无码久久av| 女人被狂躁c到高潮视频| 中文字字幕人妻中文| 中文人妻无码一区二区三区| 国产精品亚洲欧美大片在线观看 | 欧美巨大xxxx做受中文字幕| 久久av高清无码| 亚洲乱码中文字幕久久孕妇黑人 | 2019亚洲午夜无码天堂| 亚洲av无码国产一区二区三区| 亚洲av美女一区二区三区 | 精品一区二区三区在线观看|