日产亚洲一区二区三区-亚洲av无码一区二区三区电影-999在线视频精品免费播放观看-午夜精品久久久久久久

Product center

General computing, heterogeneous computing, collaborative computing, edge computing and other diversified product layout

Powerleader All-Flash Storage PLStor SF Series

PLStor 8100F, 8200F, 8300F, 8500F, 8600F, 8800F, 9800F, 18500F, 18800F intelligent all-flash storage system (hereinafter referred to as PLStor F all-flash) is a storage product designed by Powerleader for all-flash storage, which satisfies the higher demands on storage systems in the cloud era. performance, lower latency, and more flexibility. PLStor F all-flash fully inherits the rich enterprise-level features of Powerleader storage, and meets the data requirements of various applications such as OLTP/OLAP, file sharing, cloud computing, etc. in medium and large databases in terms of function, performance, reliability and intelligent management. Storage requirements, widely used in finance, government, operators, manufacturing, energy, education, medical and other industries. PLStor F all-flash storage can provide efficient, flexible and rich backup and disaster recovery solutions, effectively ensure user business continuity and data security, and provide users with excellent storage services.

Functional features
Excellent performance

A new generation of storage hardware matching flashmemory, providing leading performance solutions

All-around leading specs:PLStor F all-flash uses a multi-core andmulti-threaded high-performance processing platform . RDMA technology is used for high-speedinterconnection between controllers. It supports 32GbpsFC/100Gbps Ethernet and other host interfaces. Theback end uses NVMe over Fabric ( 100Gbps )/SAS 3.0(12Gbps) high-speed interface. , to meetthe needs of high concurrency and low latency access to user databases .

Flexible scalability:supportshigh-speed enterprise-class NVMe SSD drives and SAS SSD drives , a singlesystem can be flexibly expanded to 16 controllers, 12TB cache, and provides millions of IOPS , makingperformance and specifications overall leading.

Flash-orientedsystem architecture design to quickly respond to core business needs

System Architecture forAll-Flash Designs :PLStor Fall-flash memory adoptsinnovative end-to-end deep optimized all-self-developed flash memoryarchitecture design, including intelligent multi-core optimization, resource allocationalgorithm, Cache adaptive algorithm, flash memory intelligent algorithm anddriver, etc. to realize the deep integration of software and hardware in the system, ensuring SSD Onthe premise of long life, it provides faster I/O response, gives full play tothe performance of all-flash storage, ensures that users' key applicationsachieve excellent performance experience, and helps core businesses easilyenter the era of intelligent all-flash storage .

The multi-core and multi-threaded high-performanceprocessing platform ,combined with multi-stream and QoS technology, reduces SSD latency by 30 % , providingusers with higher reliability and higher performance SSD drives .


deep fusion

Equipped with PLStor OSstorage operating system, PLStor Fall-flash further leverages the advantages of integration,providing users with a unified resource pool that is integrated and flexiblyallocated, allowing user data to flow freely, and helping enterprise IT evolveto a cloud architecture.

Fusion of flash memory:Powerleaderhas a comprehensive range of flash memory products that can realizeinterconnection and interoperability of different types, grades, and generationsof flash memory ; through the multi-layered flash memory fusion of data,management, and operation and maintenance, it can achieve millions of IOPS.High performance and low latency, while ensuring the long-term reliability ofSSD.

Convergence of SAN and NAS: PLStor F all-flash can provide SAN and NASservices to meet the needs of flexible business development, improve storageresource utilization, and effectively reduce TCO. The SAN service and NASservice are directly provided by the underlying storage resource pool, which shortensthe access path of storage resources, thus ensuring the industry-leadingperformance and functions of the two services (SAN and NAS).

Convergence of storageresource pools: With built-in heterogeneousvirtualization capabilities, PLStorF all-flash can efficiently take over the storage arrays of othermainstream manufacturers (different grades, different types, different models),and integrate them into a unified resource pool, eliminating data islands,unified management of resources, automation & service orchestration; at thesame time, it can also achieve The migration of third-party devices isinterrupted without any interruption, and the migration operation is automatedand tool-based, reducing time-consuming by an average of 60%.

Convergence of Multiple DataCenters: PLStor Fall-flash provides gateway-free SAN and NAS integrated active- active solutionto achieve business continuity across data centers; supports smooth upgradefrom active- active data centers to 3DC, and provides two -site three-centerbusiness continuity guarantee; can achieve 64:1 Multi-level DC providescentralized disaster recovery and guarantee for data.

Cloud integration:Provide storage hybrid cloud solutions , realize data disaster recovery betweenprivate cloud and public cloud through cloud on-cloud resource coordination anddata flow, and help enterprise storage services to smoothly transform to cloud.


Stableand reliable

Reliable hardware design:Thecontroller, south bridge, network card, and SAS controller are multi-moduleintegrated to reduce failure points , and the reliability of the coreprocessing platform is guaranteed through module -level error recovery, ECC andother RAS technologies ; SSD hard drives are combined with wear leveling and Powerleader'spatented anti-wear leveling algorithm improves the reliability of SSD disks;the intelligent BMC management unit realizes comprehensive management andcontrol of processing platform, memory and other components, and the faultrecovery time is shortened from 2 hours to 10 minutes.

Multi-controller loadbalancing:PLStor Fall-flash memory achieves load balancing amongmultiple controllers, eliminates single points of failure, realizes high systemavailability, and protects stable online services. At the same time, multiplecontrollers can be used to accelerate the same host business concurrently,eliminating the performance bottleneck of a single controller and doubling theperformance.

Unique rapid data recoverytechnology:Using innovative block-levelvirtualization technology, the reconstruction time of 1TB data is reduced from 10hours to 30 minutes. Compared with traditional high-end storage, the risk ofdata failure caused by hard disk failure is reduced by 95%.

Rich data protectionsolutions:Hyper series data protectionsoftware includes snapshot, clone, integrated backup, remote replication,active-active, 3DC and other data protection technologies, which can meet thedata protection needs of users in the system, locally, in different places andin multiple places . Achieve 99.9999% availability to ensure user businesscontinuity and data availability.

SAN and NAS integrated active-activeprotection for core applications :PLStorF all-flash supports SAN and NAS integrated active-active,ensuring high availability of database and file services at the same time. WithHyperMetro AA active-active, load-balancing active-active mirroring andnon-disruptive cross-site takeover can be implemented between storage systems,ensuring zero loss of user key application data and zero business interruption,so that users' core application systems are not troubled by downtime . At thesame time, the gateway-free design can effectively reduce the user'sacquisition cost and deployment complexity. A single set of equipment can besmoothly upgraded to active-active, and can be further extended to two -sitethree-center solutions.


Intelligent management

Intelligent operation andmaintenance management: intelligent remote monitoring,7*24 active monitoring and remote maintenance in the storage cloud, automaticinspection, minute-level fault detection, automatic fault reporting and ordercreation; intelligent fault diagnosis, end-to-end path visualization andperformance from host to storage Correlation analysis to achieve automaticfault location.

Intelligent prediction andevaluation:intelligent risk prediction, basedon multi-dimensional analysis and prediction of harddisk/configuration/capacity/performance, etc., to identify system risks inadvance; intelligent business planning, analysis of host business loadcharacteristics and system capacity prediction, plan system performance andcapacity requirements in advance .

Technical specifications

name

8100F

8200F

8300F

8500F

8600F

8800F

Control Frame Properties


Architecture

all-flash

delay

<1ms

processor

multi-core processor

Maximum system cache

256GB

512GB

2TB

4TB

8TB

12TB

Maximum number of controllers

8

8

16

16

16

16

Supported storage protocols

FC, iSCSI, NFS, CIFS, HTTP, FTP

Front End Channel Port Type

8/16/32Gbps FC, 1/10/25Gbps Ethernet

8/16/32Gbps FC, 1/10/25/40/100Gbps Ethernet

Backend channel port type

SAS3.0

NVMe over Fabric/SAS 3.0

Maximum number of hot-swappable I/O modules (per controller)

2

2

3

6

6

6

Maximum front-end host interfaces (per controller)

18

18

20

twenty four

28

28

Maximum number of disks with dual controllers

300

750

1000

1200

1500

1 8 00

hard drive type

SAS SSD

NVMe SSD, SAS SSD

RAID support

0,1,5,6,10,50 etc.

Key Software Features


data protection software

HyperSnap; HyperClone

HyperCopy; HyperMirror

HyperMetro; HyperReplication

HyperLock; HyperVault

Critical business assurance

SmartQoS

SmartPartition

Resource Efficiency Improvement

SmartMigration; SmartVirtualization

SmartMulti - tenant; SmartQuota

SmartDedupe; SmartCompression; SmartThin

SmartMotion; SmartErase

storage management software

UltraPath; BCManager

DeviceManager; eSight

eService

Virtualization feature support


Heterogeneous virtualization

Integrate equipment storage resources of mainstream manufacturers, and uniformly manage and allocate storage resources flexibly

block-level virtualization

Balanced data distribution, fast recovery from failures

physical properties


power supply

AC : 200V ~ 240V AC±10%

DC: 240V DC±2 0%

weight

≤24kg

≤2 5Kg

≤39Kg

Dimensions (D×W×H)

520mm*447mm*86.1mm

2.5-inch controller frame:

520mm*447mm*86.1mm

NVMe controller enclosure:

6 2 0mm*447mm*86.1mm

2.5-inch controller frame: 820mm*447mm*86.1mm

NVMe controller enclosure: 920mm*447mm*86.1mm

Working temperature

When the altitude is -60~+1800m, the ambient temperature is 5°C~40°C; when the altitude is 1800m~3000m, the ambient temperature decreases by 1°C for every 220m increase in altitude.

Working environment humidity

10 % to 90 % R.H.




name

9800F

18500F

18800F

Control Frame Properties


Architecture

all-flash

delay

<1ms

processor

multi-core processor

Maximum system cache

4T

Maximum number of controllers

16

32

Supported storage protocols

FC, iSCSI, NFS, CIFS, HTTP, FTP

Front End Channel Port Type

8/16/32Gbps FC, 1/10/25Gbps Ethernet

8/16/32Gbps FC, 1/10/25/40/100Gbps Ethernet

Backend channel port type

SAS3.0

NVMe over Fabric/SAS 3.0

Maximum number of hot-swappable I/O modules (per controller)

28

Maximum front-end host interfaces (per controller)

80

Maximum number of disks with dual controllers

2000

2400

3200

hard drive type

SAS SSD

NVMe SSD, SAS SSD

RAID support

0,1,5,6,10,50 etc.

Key Software Features


data protection software

HyperSnap; HyperClone

HyperCopy; HyperMirror

HyperMetro; HyperReplication

HyperLock; HyperVault

Critical business assurance

SmartQoS

SmartPartition

Resource Efficiency Improvement

SmartMigration; SmartVirtualization

SmartMulti - tenant; SmartQuota

SmartDedupe; SmartCompression; SmartThin

SmartMotion; SmartErase

storage management software

UltraPath; BCManager

DeviceManager; eSight

eService

Virtualization feature support


Heterogeneous virtualization

Integrate equipment storage resources of mainstream manufacturers, and uniformly manage and allocate storage resources flexibly

block-level virtualization

Balanced data distribution, fast recovery from failures

physical properties


power supply

AC : 200V ~ 240V AC±10%

DC: 240V DC±2 0%

weight

≤24.95Kg

Dimensions (D×W×H)

520mm*447mm*86.1mm

Working temperature

When the altitude is -60~+1800m, the ambient temperature is 5°C~40°C; when the altitude is 1800m~3000m, the ambient temperature decreases by 1°C for every 220m increase in altitude.

Working environment humidity

10 % to 90 % R.H.



Service and Support

PowerLeader provides nationwide joint warranty, and PowerLeader 's professional after-sales service outlets across the country provide "one-stop" service response and support.

- 3-year limited on-site warranty and on-site support

- 4008-870-872 hotline response and support

For more information: please visit: http://en.powerleader.com.cn/

Correspondence address: 16th Floor, Building B, Building 7, Baoneng Technology Park, No. 1 Qingxiang Road, Longhua District, Shenzhen


PowerLeader reserves the right to change product specifications or other product information (including but not limited to product weight, appearance, size or other physical factors) without notice; the information mentioned in this article may change due to product upgrades or other reasons. resulting in changes without prior notice. The product pictures involved in this article are subject to the actual product.

Related downloads
View more >
  • Powerleader All-Flash Storage PLStor SF Series Product Paper

    2024-11-14

主站蜘蛛池模板: 无人区码一码二码w358cc| 九九久久自然熟的香蕉图片| 亚洲人精品午夜射精日韩| 国产成人a亚洲精v品无码| 久久男人av资源网站无码| 毛茸茸的中国女bbw| 好大好深好猛好爽视频免费| 少妇激情一区二区三区视频| 狠狠综合久久av一区二区 | 国语精品一区二区三区| 国产性自爱拍偷在在线播放| 里番本子纯肉侵犯肉全彩无码| 久久午夜无码免费| 情侣黄网站免费看| 亚洲视频一区| 午夜免费啪视频| 久久九九久精品国产| 醉酒后少妇被疯狂内射视频| 亚洲精品无码av片| 国产初高中生在线视频| 男人和女人做爽爽视频| 国产欧美精品一区二区三区-老狼 亚洲成a v人片在线观看 | 久久久亚洲精华液精华液精华液| 成人免费a级毛片| 在线无码视频观看草草视频| 久久久久久国产精品无码下载| 人妻av资源先锋影音av资源| 亚洲日韩国产欧美一区二区三区| 色视频综合无码一区二区三区| 黑人巨大跨种族video| a级国产乱理伦片在线观看al| 精品性高朝久久久久久久| 成人试看120秒体验区| 亚洲精品自产拍在线观看| 久久99精品国产麻豆不卡| av无码免费看| 精品深夜av无码一区二区老年| 九九综合九色综合网站| 国产精品麻豆成人av电影艾秋| 99久久精品国产成人综合| 精品欧洲av无码一区二区|